Stereo192 SRC is a two channel hi-end Sample Rate Converter recording and mastering applications. The main feature of this converter is its outstanding sound quality which makes it suitable for the most demanding projects when preserving the original signal quality is a required. The sonic transparency of this unit far exceeds most of the software SRC algorithms.
The unit can operate in two modes;
-Synchronous SRC- where the output clock is synchronized to input clock. This mode is recommended for Digital to Digital transfers.
-Asynchronous SRC- where the output clock is generated by internal clock generator. This mode is recommended for Digital to Analog transfers where the SRC proceeds a D/A converter in order to upsample the signal and provide 100% jitter immunity and removal.
Conversion: Synchronous or Asynchronous
Input Resolution: 16-24 bit
Output Resolution: 24 bit or 16,20 bit
Input Sample rates: Any frequency btwn 32-200kHz
Output Sample rates: Any frequency btwn 32-200kHz, can be user set
with 1Hz accuracy or standard frequencies can be
selected.
Dynamic Range: 144dB
THD+Noise: -140dB (<0.0003%)
Internal clock jitter: <10picoseconds
Digital Inputs: Hi-speed (32-200kHz) AES/EBU, SPDIF,Optical
Digital outputs: Hi-speed (32-200kHz) AES/EBU and SPDIF
External Sync.: Wordclock in and out.
Wordclock Out: Wordlock Out can be used a ultra stable 10ps
house clock source with digital FS display.
Can be terminated w/ 75 Ohm
Mains: 100/115V-220/240V 50/60Hz switchable
Dimensions: 1/3 rack space wide x 1U high x 8” deep
(5.5”x 1.6”x 8”)
Weight: 3.5 pounds